MRF-301 A/C service station, with high performance price ratio, is a newly-developed special recovery & recharging unit for R134a refrigerant. |
Technical Features |
- Special recovery & recharging unit for R134a refrigerant.
- Integrating five major functions and nine subsidiary functions into one.
- Unique pipelines control, quick recovery and recharging.
- Built-in microcomputer control ensures the convenient operation, consistent performance and safety.
- High accuracy electronic scale measures the quantity of recovered and recharged refrigerant.
- Live display the running status, and make it convenient to monitor the pressure on high-pressure port, low-pressure port and pressure in the refrigerant tank. |
|
|
|
Five major functions & Nine subsidiary functions |
Recovery: To recover the residual R134a refrigerant from A/C system. The recovered refrigerant will be stored automatically after a series of purge process (such as drying, flirtation, oil and gas separating, etc.), which makes the reuse of refrigerant convenient, natural, energy saving and efficient. |
Recharging: Recharge automatically according to the quantity set by auto A/C system. |
Recycling: Special-made pipelines ensure that the refrigerant inside tank of the unit is recycling, which keeps high purity of refrigerant and enhances recharging pressure. |
Vacuuming: To vacuum for A/C system and remove water and air thoroughly. |
Auto Mode: Automatically perform the whole process of recovery, draining used cooling oil, vacuuming, recharging cooling oil and refrigerant according to the program. |
Self Test: To test solenoid valves, vacuum pump, compressor and other important components inside the unit, and check malfunction of them. |
Inquiry: To inquire system for the accumulated running time and running frequencies, and monitor the using situation of the unit. |
Calibration for electronic scale: Calibration of electronic scale ensures the high accuracy of measurements. |
Vacuuming for system:To vacuum for pipelines inside the unit, and remove the air from pipelines. Time setting for cooling oil filling: Under Auto Mode, time for cooling oil filling can be set.
Adjustment for the error of recharging: To compensate for refrigerant remained in pipelines according to the climate change, and ensure recharging accuracy of A/C system.
|
Zero clearing: The system will return to zero automatically and keep the default value, under the condition that users take improper action and cause the abnormity of set parameters.
|
Leakage test: To perform the leakage test for A/C system according to the pressure change of the vacuum degree. |
Automatic alarm: System tests empty tank, full tank or high-pressure and makes alarm automatically, and will prompt you malfunction code to make the maintenance convenient and ensure that the unit run safely. |
Working conditions & Specification |
Temperature: 10°C~45°C
Relative humidity: <85%
Input power: AC220V~50/60Hz
Vacuum pump: 3.5CFM-220V-280W
Compressor power: 3/8HP
Accuracy of electronic scale: ±10g
Maximum weight of electronic scale: 30Kg
Capacity of refrigerant tank: 13.6 kg
Maximum recharging speed: 150g/s
Average recharging speed: 60g/s
Maximum working pressure: 17.5bar |